Application field

Geoelectric survey in an livestock establishment

Back to list

Ⅰ 、An introduction

This report details the geophysical prospecting works carried out for  hydrogeological purposes on a property located 19 km north of Tartagal,  Santa Fe. The objective of the work is to locate areas with potential  underground water storage with aptitude for cattle watering. The property  has an area of approximately 13 km2

Location

Figure 1 shows the location of the investigated site and Figure 2 shows the  parametric transect. This site was chosen because it has the presence of  groundwater in quality and quantity according to that required. In Figure 3,  Figure 4 and Figure 5 the transects on which the exploratory studies were  carried out are shown. The method implemented was that of tomography.  electrical resistivity

Figure 2. Electrical resistivity tomography transect ERT 001 (parametric)

Figure 3. Electrical resistivity tomography transect ERT 002

Figure 4. Electrical resistivity tomography transect ERT 003

Figure 5. Electrical resistivity tomography transect ERT 004

The property has a group of reservoirs for the accumulation of rainwater. It  has a hole on the access road to the house that is dry. According to the owner, other perforations made on the property illuminate water with high salinity,  not suitable for livestock watering.

Ⅱ、Drainage network

To calculate the network, a digital elevation model taken from the IGN  website was used. The DEM has a resolution of 5m. Drainage network is  shown in Figura 8.

1.png

Figura 8. Drainage network

It can be seen that the standard is at the highest levels locally. The drainage  network is shown superimposed on it. The latter shows how surface water  runs to the E and W of the property. Four sites of interest emerge from this  network. They are indicated by circles superimposed on the image. They  correspond to the closing points of the micro-basins where the underground  water flow lines would be expected to converge, based on the hypothesis that  the latter copy the surface flow lines.

Ⅲ、Survey analysis

ERT

Measurements were carried out using the GD-10 equipment from  GEOMATIVE, using different methods for data collection (arrangements). The  separation between electrodes was 10 m for a total of 24 electrodes for the  ERT001, ERT003 and 48 electrodes for the ERT002 and ERT004. The line  length used for the ERT001 and ERT003 scans was 230m while for the ERT002  and ERT004 it was 470m. The arrangements used were Wenner Alpha and  Wenner-Schlumberger and Dipole-Dipole. For data interpretation and investment, the RES2DINV program was used. Below are the images of the tomographies, where Figure 13 and Figure 14  show the profiles of the real resistivity obtained vs depth, after the inversion  carried out using the interpretation program for ERT001 and Figure 15 and  Figure 16 show the corresponding to ERT002. The reiteration of  measurements in different arrangements for each transect allows evaluating  the interpretive homogeneity and the best performance of the software with  the minimization of errors..

ERT models

1.png

Figura 9. ERT001, Wenner Alpha array.

2.png

Figura 10. ERT00, Schlumberger array.

3.png

Figura 11. ERT001, arreglo Wenner-Schlumberger array

4.png

Figura 12. ERT002, Wenner alpha array

5.png

Figura 13. ERT002, Wenner-Schlumberger array

6.png

Figura 14. ERT003, Wenner Alpha array.

7.png

Figura 15. ERT003, Wenner-Schlumberger array

8.png

Figura 16. ERT003, Dipolo-Dipolo array.

9.png

Figura 17. ERT004, Wenner Alpha array.

10.png

Figura 18. ERT004, arreglo Wenner-Schlumberger array

11.png

Figura 19. ERT004, Dipolo-Dipolo array

Figure 20, Figure 21, Figure 22 and Figure 23 shows, on a satellite image,  the electrical resistivity models obtained.

1.png

2.png

3.png

4.png


Ⅳ、Results

ERT001 

The tomography was carried out in order to determine the geoelectric  characteristics that would correspond to the areas where there is a presence  of groundwater with low salinity. It was carried out in the EW direction. The  Wenner Alpha array reached a depth of exploration of around 40m while the  Schlumberger and Wenner Schlumberger reached 48m. The error in the  adjustment of the first model was 1.26% 1.49% in the second in the third it  was 1.27%. Progressive 0 is to the west. In the images obtained using the  three arrangements, it is observed, in general, that the behavior of the  apparent resistivity is quite homogeneous. The site of interest, where there  is a catchment work, corresponds to the progressive 190. At that site, the  behavior of the variable in question reaches its maximum, around 10 ohm.m.  This resistivity value could be due to the fact that the subsoil, in this sector,  contains stored water with lower conductivity. The anomaly extends to depths  of 24 m. From that depth, the image shows a very low resistivity behavior  that would correspond to the brackish aquifer. 

ERT002 

The tomography was carried out in the SE-NW direction. The Wenner Alpha  array reached an exploration depth of around 91.2m while the WennerSchlumberger reached 104.8m. The error in the adjustment of the first model  was 1.37%, while that of the second was 1.76%. A two-layer behavior is  observed. The first, with a thickness of around 13m, has average resistivity  values, no greater than 4 ohm.m. The lower layer has low resistivities, with  values less than 1.5 ohm.m. The brackish aquifer would be housed in this. 

ERT003 

The tomography was carried out in the SSO-NNO direction. The Wenner Alpha  array reached an exploration depth of 39.6 m, the Wenner-Schlumberger  reached 48 m and the Dipole-Dipole only 31.9 m. The error in the adjustment  of the first model was 1.72%, of the second, 2%, while that corresponding to  the third was high, 12.1%. A two-layer behavior is observed. Like TRE002,  the first layer, with a thickness of around 13m, has average resistivity values,  no greater than 4 ohm.m. The lower layer has low resistivities, with values  less than 1.5 ohm.m. The brackish aquifer would be housed in this. In this  transect, two points of interest were marked on the ground, an issue that will  be discussed later. 

ERT004 

The tomography was carried out in the SW-NW direction. The Wenner Alpha  array reached an exploration depth of 91.2 m, the Wenner-Schlumberger  reached 104.8 m and the Dipole-Dipole only 24.9 m. The error in the  adjustment of the first model was 2.9%, of the second, 5.7%, while that of  the third was high, 11%. Again a two-layer behavior is observed. The first  layer in this case is more heterogeneous, with varying thicknesses from 13  to 25 m. This layer has medium to high resistivity values, not greater than 7  ohm.m. The lower layer has low resistivities, with values less than 1.5  ohm.m. The brackish aquifer would be housed in this. In this transect, two points of interest were marked on the ground with stakes, an issue that will  be discussed later.

leave comments